<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-13 18-04-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.20 MHz 4/5, 55 dBuV LOOP
Pilot RDS Phase Difference
6.9 kHz 31 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
7 kHz 68 kHz 5185 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,3 dBr 6,41 dBr 7,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" LOOP " 6459 25 (Country) 1 0 1 1 --:--
RT
"KUUMAA - Valoa varten "
AF EON
92.9, 94.8, 98.3, 105.1, 106.1, 106.2 MHz -
FM Scope Max at: 68 kHz MIN: 7 kHz % above 76 kHz: 0,0000 Acquired: 2025/11/13 18.03.13 Total samples: 5185 Equivalent time: 0:04:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 7,5 dBr MIN: 5,3 dBr AVE: 6,41 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2025/11/13 18.03.13) 17.50 17.52 17.54 17.56 17.58 18.00 18.02 0 2 4 6 8 Pm [dBr]